Introducing Diamed’s DiaTEC PCR Tube & Cap Series  
Features: 
    - Ultra Thin Walls  ensure efficient thermal transfer and thus maximum yield.
 
    - Standard PCR Tube Capacity  is 0.2 ml & Low Profile PCR Tube Capacity is 0.1 ml
 
    - 8 Strip Tubes with  individually attached caps utilize a patented angular hinge, minimizing overlap  of hinges and caps when placed in blocks or racks.
 
    - Optically Clear Caps  are designed for real-time PCR or QPCR applications
 
    - White Tubes provide  greater reflection enhancing signal detection for real-time PCR or QPCR  applications
 
    - Specially formatted  medical grade raw material offers superior clarity ensuring easy high  visibility of contents
 
 
  
Superior Quality   All DiaTEC Individual PCR Tube & Cap products are precision  manufactured to the industry’s most rigorous quality control standards and are  INDEPENDENTLY CERTIFIED for the following: 
    - Free of  Rnase, Dnase, DNA & Endotoxins
 
    - Sterile  product is certified free from Rnase, Dnase, pyrogen, DNA & PCR Inhibitor  Free
 
    - Products may  be sterilized at 121o C at 100 kPa for 10 minutes
 
    - All products  are manufactured from FDA Approved virgin polypropylene in North America at an  ISO9001:2008 certified state of the art automated facility
 
 
Great Pricing:        We make sure our entire product listing is  accessible to you at ultra-competitive prices. 
Environmentally Friendly: All DiaTEC products are made out of 100% recyclable  plastics. Diamed has been conscious about the environment for over a decade,  long before it became popular--or cool--to be green. That is why we do our best  to respect our planet. 
DiaTEC PCR Tube & Cap products are produced  consistently to high exacting standards; for example wall thickness is produced  uniformly to a thickness of 0.20 mm. This enables rapid and efficient thermal  transfer, one of the essential elements for maximum yield. DiaTEC PCR Tube  & Cap Series offers a wide selection of products to meet your needs now and  as they evolve and develop, by introducing innovative new products. 
DiaTEC  Product Testing 
All DiaTEC products are manufactured from the finest raw  materials using precise production techniques that provide consistent quality  performance. All primary products are made from virgin polymers and contain no  recycled, reprocessed, or altered plastics that might introduce contamination  or defects. All PCR Tubes & Caps are manufactured under stringent controls  in an ISO 9001:2008 certified facility. 
Every lot of each product can be traced to the  corresponding raw materials and production date. In addition to continual  in-process control monitoring, all product lots are sampled after packaging and  tested in our quality control laboratory as well as independent laboratories.  The result is a contaminant-free product of the highest quality. 
    - RNase/DNase-Free
 
    - Human DNA and PCR  Inhibitor-Free
 
    - Non-pyrogenic
 
 
Autoclaving Recommendation 
    - Autoclavable at 121°  C & 15 psi for 10 minutes
 
    - No dry heat autoclaving.
 
    - Ensure water reservoir is full.
 
    - Allow plastic to cool to 80° C before removing from  autoclave container.
 
 
  
Potential Contamination and Testing Method 
    
        
            | 
             Impurities 
             | 
            
             Type 
             | 
            
             Source 
             | 
            
             Adverse Affects 
             | 
            
             Assay Method 
             | 
            
             Assay Specifications 
             | 
         
        
            | 
             Dnase 
             | 
            
             Enzyme 
             | 
            
             Human contact,    saliva 
             | 
            
             Degraded sample    following purification and PCR assays 
             | 
            
            
                - Products rinsed in LAL reagent water
 
                - Product extracts exposed to DNA    standard in a fixed volume of buffer
 
                - DNA standard incubated at 37°C for 1    hour
 
                - DNA samples run on agarose gel and    evaluated for degradation
 
             
             | 
            
             <10 – 7    Kunitz u/ µl 
             | 
         
        
            | 
             Rnase 
             | 
            
             Enzyme 
             | 
            
             Human contact, oils from    hands, face, arms & hair 
             | 
            
             Could destroy RNA,    the template cDNA synthesis, TR-PCR and other assays 
             | 
            
            
                - Similar to DNase test, except product    extracts are exposed to an RNA standard in a fixed volume of buffer
 
             
              
             | 
            
             <10 – 9    Kunitz u/ µl 
             | 
         
        
            | 
             DNA 
             | 
            
             Nucleic Acid 
             | 
            
             All Living Organisms 
             | 
            
             False-positive    results in DNA applications 
             | 
            
            
                - Product rinsed in LAL reagent water
 
                - Product extracts are subjected to a    PCR reaction using human and mouse genomic DNA primers for 52 cycles
 
                - Samples run on agarose gel and    evaluated for the presence of amplification. A 90 bp positive control is run    in parallel with the test samples
 
             
             | 
            
             No amplicons    detected (Sensitivity 30pg) 
             | 
         
        
            | 
             Pyrogen 
             | 
            
             Endotoxin 
             | 
            
             Bacteria found    universally in air, soil & human contact 
             | 
            
             Contamination of    drug manufacture, cell culture, purification & medical testing 
             | 
            
            
                - Limulus amebocyte lysate (LAL) test    method utilized per USFDA (1987; USP 23 NF 18, 1994)
 
                - Product extracts are tested by Gel    Cloth Method for 1 hour in endotoxin-screened distilled water
 
                - LAL test results include negative and    positive controls, standard endotoxin control, and product extracts
 
                - After a fixed incubation period, the    reaction mixture is observed. The test is positive if a clot has formed and    remains intact at the bottom of the tube after a 180° inversion
 
             
             | 
            
             < 0.06 EU/ml 
             | 
         
    
 
12  Strip Tubes & Caps – Cap Only
  
    
        
            | 
             Product Code 
             | 
            
             Description 
             | 
         
        
            | 
             DIATEC420-1825 
             | 
            
             12-Strip Dome Cap for 0.1/0.2 ml PCR Tubes or 96 Well Plates,    Natural, Bulk, Non-Sterile, 80/pk 
             | 
         
        
            | 
             DIATEC420-1826 
             | 
            
             12-Strip Optically Clear Flat Cap for 0.1/0.2 ml PCR Tubes or 96    Well Plates, Natural, Bulk, Non-Sterile, 80/pk 
             | 
         
    
  
				
          
		| 
         | 
       
    
       | 
      
	
          | 
       
   
  | 
 
|  *Please select the quantity for each item you wish to order and click the 'Add To Cart' button below. | 
 
  | 
 
     
     
               
     
        | Displaying 1 to 4 (of 4 products) | 
        Result Pages:  1  | 
      
     
       |  
          | 
       
	     
 
   
	
	
         |